SPECIFICATIONS
Cellulose extraction thimbles Øext 26 x 60 mm.
Working temperature of 90 to 240 °C.
Solvent recovery 60 to 80 %.
Solvent volume (by sample): up to 50 ml.
Program memories: 16.
Extraction time <>: from 0 to 99 minutes.
Extraction time <>: from 0 to 99 minutes.
Time to recuperate solvents: from 0 to 99 minutes.
-

EQUIPMENT DESCRIPTION
Integral extraction and filtration.
No sample transfer reduces the risk of sample loss, since the tubes,crucibles and filtre are transferred with the samples in place.
Excellent results due to reproducible operating conditions.
Easy sample handling due to the special crucible support stand.
Versatile and precise test procedure that allows the samples to be weighed at various stages in the extraction process.
-

Gel Documentation
we supply a range of gel documentation systems, from our entry level microDOC Basic up to the all-in-one DNA and protein imaging omniDOC.TheomniDOC system presents a simple but sophisticated imaging solution, whilst offering many of the features incorporated within the highest specification systems, but without the added price. The omniDoc is suitable for imaging most fluorescent and colorimetric gels, with a high resolution 5 mega pixel CMOS sensor with slide-out UV transilluminator and optional blue epiillumination module and white light table.>we also supply a range of chemiluminescence documentation systems for both chemi and fluoresense imaging. All systems include intuitive acquisition and analysis software to make capturing and analysing gels as easy as possible
Gel documentation is a fundamental part of electrophoretic analysis. we provide a range of gel documentation systems suitable for both conventional ethidium bromide stained DNA, as well as modern ethidum bromide alternatives such as runSafe. Our omniDOC is a top of the range system taht can include blue, white and UV illumination. The compact microDOC system can be supplied with a UV transilluminator or blue light table and is equipped with a touch screen for PC free operation. The microDOC basic is the most economical option, providing excellent images at an affordable cost.
-

Common Specifications
Heating |
Direct Immersion Sheath Heater |
Temp. Range |
ambient + 5 oC ~ 120 oC |
Accuracy |
± 0.2 oC at 37.0 oC (JSWB-11T) |
Uniformity |
± 0.8 oC at 37.0 oC (JSWB-11T) |
Control |
Digital Microprocessor PID Temperature Controller |
|
3-Zone Temperature Control Algorithm |
|
3-Point Temperature Calibration |
|
1-Point Temperature Offset Calibration |
Sensor |
Class A Pt-100 Ω Sensor |
Safety |
Over-Temperature Cut-Off |
|
Over Current Cut-Off |
Material |
Body – Epoxy Powder Coated Steel |
|
Bath – Electro-polished Seamless Stainless Steel 304 |
|
Heater Cover – Perforated Stainless Steel 304 |
Electric |
220±10% VAC 50/60Hz 1-Phase |
Plug config. |
CEE 7/7 Schuko or BS 1363 |
-

High Speed Refrigerated Centrifuge |
VS-18000M |
Max. RPM |
18,000RPM |
Max. RCF |
23,545 × g |
Max. Capacity |
300ml, 50ml × 6 Tubes |
Temperature Range |
-20℃ to 40℃ |
-

Hand-Held Homogenizers
Specifications
Volume Processing Range: 0.05ml – 5L*
Power Rating: 576 Watts
RPM Range: 5,000 – 30,000
Speed Control: Analog; Variable Speed
Noise rating: 72 dB
Digital Homogenizer
Volume Processing Range: 0.05ml – 3.5L*
Power Rating: 576 Watts
RPM Range: 0 – 30,000 (120V) / 0 – 28,000 (220V)
Speed Control: Digital; Variable Speed
Noise rating: 68 dB
-

Horizontal Electrophoresis System
Our multiSUB Horizontal Electrophoresis tanks provide an easy to use and flexible platform for all your horizontal electrophoresis requirements.With a wide range of tanks and tray sizes as well as many comb options, these systems can handle all manner of electrophoresis experiments. Our multiSUB series of Horizontal Gel Units offers the most versatile solution for DNA and RNA agarose gel electrophoresis currently on the market
Vertical Electrophoresis Systems
The omniPAGE range comprises three sizes of gel chamber, Mini 10 x 10cm, Mini Wide 20 x 10cm and WAVE Maxi 20 x 20cm. Each system have a guaranteed leak proof seal resulting in trouble free and rapid gel casting.These systems are ideal for running precast or handcast polyacrylamide gels for SDS-PAGE or Native PAGE
-

Product Features
- Optimized for high density microbial growth
• Wide ranges of vessels of single, double or bowl types from 1 L to 10 L
• Individually controlled four peristaltic pumps for pH, DO, anti-foam and feeding
• Intuitive control with 12″ Android Tablet
• Accurate PID temperature control
-

Laboratory Microscopes inverted research microscope is a new inverted research microscope producing brilliant images for the examination of living cells, organisms and several other specimens in large flasks, combining brightfield, darkfield and phase contrast techniques for the most demanding users.
-

-

-

Media preparation MEDIACLAVE 10/30 Media Sterilizer Media clave 30 liter Fast, reproducible and safe media sterilization The preparation of agar medium is a routine task in today’s laboratories. The typical workflow is to dissolve the components in a flask followed by sterilization in an autoclave. However, this procedure has several disadvantages.How it works The…
-

Microplate Dispenser WELLJET Reagent Dispenser And Dispenser Stacker A revolution in reagent dispensing! The WELLJET reagent dispenser and dispenser stacker offer low cost, fast, and precise bulk dispensing while saving valuable bench space. The cost-efficient and handy solution for rapidly dispensing reagents into microplates. Increase your sample throughput in a snap! The WELLJET dispenser…
-

Reagent |
Suitable for all kinds of ELISA reagents |
Reading range |
0.000-4.000A |
Accuracy |
0.008A |
Stabllity |
0.003A |
Resolution |
0.001A |
Type of microplate |
Flat bottom 48/96 Well |
Photodetector |
Silicon Photodiode |
Port |
USB-B |
-

Technical parameters:
microwave source |
2450MHz,0-1000W continous and automatic adjustment with temperature programming, PID technology |
microwave oven cavity |
Stainless steel cavity with large volume, multilayer anticorrosive PFA Teflon painting. |
temperature measurement control system |
Dual-channel temperature detection (DTD) technology, automatic judgement temperature measurement mode. infrared temperature measurement range 0℃ to 900℃ with deviation of ±1℃, Pt100 thermocouple temperature measurement range 0 to 300℃with deviation of ±1℃. |
operating temperature |
standard configuration instrument’s maximum operating temperature is 300℃ and the maximum theoretical operating temperature is 900℃ (peculiar configuration). |
video system |
Standard configuration photographic device built-in furnace chamber and 7’’ color TFT-LCD monitor. Reaction process will be displayed in time. |
stirring system |
Standard configuration magnetic stirring system with revolving speed of 30 to 1600 r/min, digital mechanical paddle-type stirring system with revolving speed of 30 to1700 r/min. |
reaction vessel |
50-1000ml standard reaction vessel, condenser, backflow and liquid adding accessory. |
operating ambient temperature/humidity |
0-40 °C / 15-80% RH |
Main Technical Parameters Closed Microwave Digestion/Extraction System
Microwave frequency |
2450MHz |
Installed power |
1800W |
Maximum output power |
1000W, non-pulse continuous automatic variable frequency control |
Turntable design |
Load 8 MP-100 closed digestion vessels at same time |
Pressure measurement and control system |
Piezoelectric crystal pressure sensor, pressure control range :0-10MPa (1500 psi), accuracy ± 0.01MPa |
Temperature measurement and control system |
High-precision platinum resistor temperature sensor, temperature range :0-300°C, accuracy ±1℃ |
Outer vessel material |
Explosion-proof outer vessel made of aerospace composite fiber |
Inner vessel material |
TFM material |
Chamber exhaust system |
High-power anticorrosion axial fan, exhaust speed: 3.1 m3/min |
Operating ambient temperature |
0-40 ° C |
-