Showing 1–16 of 33 results
-
Biological safety cabinet
Specifications
Class Class II Type A2 Air Flow Vertical Laminar Flow 70 % Recirculation 30 % Exhaust Filtration Aluminum Frame Mini-Pleated HEPA Efficiency HEPA : 99.993% for 0.3 um particle removal Controller Microprocessor Control -
Blood Bank Refrigerator
Medium Blood Bank Refrigerator +4 °C Upright, Large Capacity – 532 L True Dual Technology Double Panel Glass Door Forced Air Cooling Single Compressor Technology Large Blood Bank Refrigerator Double door +4 °C Upright Model – 1381 L. True Dual Technology Medical Device Class IIA Chart recorder Stainless Steel Drawers Double Pane Glass Door Storage…
-
Circulaire®Hybrid Fume Cupboard
Product Specification
Model HFC 1200 HFC 1500 HFC 1800 External (W x D x H) 1203mm x 942mm x 2562mm 1503mm x 942mm x 2562mm 1803mm x 942mm x 2562mm Working (W x H) 900mm x 1300mm 1200mm x 1300mm 1500mm x 1300mm Total Airflow 389m3/hr 488m3/hr 578m3/hr Recirculated Airflow 189m3/hr 288m3/hr 338m3/hr Exhausted Airflow 200m3/hr 200m3/hr 240m3/hr Filter Activated Carbon, H14 HEPA or Carbon-HEPA Combo Power 230 v 230 v 230 v Sound Circa. 56dB Circa. 56dB Circa. 55dB -
Deep freezer
Deep freezer Medium ULT Freezer ULUF 450-2M -40 °C/ -86 °C Ultra Low Temperature from 100 L to400 L Single Compressor Technology Filterless Construction Direct Cooling Heated Door Frame 100% HCFC & CFC Free Heated Vacuum Release Value
-
EDUCATIONAL Microscopes
EDUCATIONAL Microscopes BIOLOGICAL MICROSCOPES Microscope with camera monocular The B-150 series has been designed to fulfill all requirements of educational laboratories. Obtain clear images at three (40x, 100x and 400x) or four (40x, 100x, 400x and 600x or 1000x) magnifications with 18mm field number. All in a compact and easy to carry size….
-
Heated Digital Water Bath
Common Specifications
Heating Direct Immersion Sheath Heater Temp. Range ambient + 5 oC ~ 120 oC Accuracy ± 0.2 oC at 37.0 oC (JSWB-11T) Uniformity ± 0.8 oC at 37.0 oC (JSWB-11T) Control Digital Microprocessor PID Temperature Controller 3-Zone Temperature Control Algorithm 3-Point Temperature Calibration 1-Point Temperature Offset Calibration Sensor Class A Pt-100 Ω Sensor Safety Over-Temperature Cut-Off Over Current Cut-Off Material Body – Epoxy Powder Coated Steel Bath – Electro-polished Seamless Stainless Steel 304 Heater Cover – Perforated Stainless Steel 304 Electric 220±10% VAC 50/60Hz 1-Phase Plug config. CEE 7/7 Schuko or BS 1363 -
High Speed Refrigerated Centrifuge
High Speed Refrigerated Centrifuge VS-18000M Max. RPM 18,000RPM Max. RCF 23,545 × g Max. Capacity 300ml, 50ml × 6 Tubes Temperature Range -20℃ to 40℃ -
Homogenizers
Hand-Held Homogenizers
Specifications
Volume Processing Range: 0.05ml – 5L*
Power Rating: 576 Watts
RPM Range: 5,000 – 30,000
Speed Control: Analog; Variable Speed
Noise rating: 72 dBDigital Homogenizer
- Specifications
Volume Processing Range: 0.05ml – 3.5L*
Power Rating: 576 Watts
RPM Range: 0 – 30,000 (120V) / 0 – 28,000 (220V)
Speed Control: Digital; Variable Speed
Noise rating: 68 dB -
Hotplate Stirrer
Specifications
Dimensions. Top Plate: 7″ x 7″ (17.8 x 17.8cm)
Temperature: Aluminum: Ambient +5° to 400°C
Temperature Stability: Aluminum +or- 2%
Speed Range: 60 to 1600 RPM
Speed Stability: +or- 2%
Maximum Capacity: 2500ml -
Laboratory Microscopes
Laboratory Microscopes inverted research microscope is a new inverted research microscope producing brilliant images for the examination of living cells, organisms and several other specimens in large flasks, combining brightfield, darkfield and phase contrast techniques for the most demanding users.
-
Media preparation
Media preparation MEDIACLAVE 10/30 Media Sterilizer Media clave 30 liter Fast, reproducible and safe media sterilization The preparation of agar medium is a routine task in today’s laboratories. The typical workflow is to dissolve the components in a flask followed by sterilization in an autoclave. However, this procedure has several disadvantages.How it works The…