CO2 Incubator(33L)
Water Jacket Type of Co2/ Incubator
ㆍSetting value and Status are shown on LED Display
ㆍDual Beam Infra-Red Sendor
ㆍRounded Corner Shelves for Pollution Prevention
ㆍStandard Size can be used on various use purpose
ㆍEfficiency Double Stackable for saving space
ㆍTrustworthy Safety device for GAS monitor,
Over Heating and Water Level
ㆍAvailable using in clean bench for Pollution Prevention
ㆍGas Seal Screen to be reduced GAS Consumption( Option )
Feature
VS-9000C(33Liter) | VS-9000GC(33Liter) |
. The best condition on Co2 test over than room temperature | |
. This unit is the incubator for Tissue culture room of hospital, Laboratory and
Food chemistry room and others to be cultured common germs (colon bacterium , Vacteria, etc..). Beside of germs culturing, this unit is used for Co2 test, environmental change test and etc.
|
|
. Precision control is possible by DIGITAL PID CONTROLLER. | |
. Precision Co2 Test (Water Jacket Type) | |
. Realization of precision temperature distribution are possible by forced air circulation. | |
. Auto tuning function for high degree of precision | |
.Stackable 2 stage for saving space |
Description
HF180 Co2 Incubator
HF180 CO2 Incubator Advantage:
- 180℃ high temperature dry heat sterilization
- HEPA filter to provide 100 grade air cleanliness culture environment
- improve the culture success rate of sensitive cells
- 8-inch touch screen
- Remote monitoring system
- Model:
HF 180
- Certification:
CE,ISO9001,ISO13485,CFDA
- Application:
Laboratory, University, Hospital
- Power Supply:
220V/50Hz(Standard),110V/60Hz(Optional)
Convenient touch screen operation, real-time dynamic parameter monitoring,
with the trend graphic display function.
High-temperature dry heat sterilization at 180℃
One-click operation, the sterilization time is <2 hours
Thorough sterilization (including thermophiles, molds,
HEPA Air Filter
Within 5 minutes after opening, it can reach 100-level cleanliness.
Culture environment is more conducive for protecting cultures
TCD and IR detection sensors
According to the user needs, the standard imported TCD and IR sensors are optional
With automatic calibration function, more reliable control.
The sensor can withstand the 180℃ of heat.
No need to take out while sterilization,with efficient and convenient for user on the daily usage.
Chassis reservoir rapid humidification design
The chassis with integral humidification device design.
The humidity recovery ability 3-4 times faster than before.
Ensuring humidity balance is conducive to cell culture.
Reviews